Check valve EURA heavy - 4" FF; Kv 56,00 FIV.08018
Code: I08018400Related products
Product detailed description
Heavy-duty check valves are essential components in pump and circulation systems where backflow prevention is critical. These valves are commonly installed in heating, plumbing, and irrigation systems to ensure unidirectional flow and protect equipment from reverse pressure surges. In industrial and commercial buildings, they are frequently used in conjunction with circulation pumps, boiler circuits, and heat exchangers. Installers must consider system pressure, temperature limits, and flow characteristics when selecting and fitting these valves.
The IVAR EURA heavy check valve is suitable for applications involving continuous flow and moderate temperature conditions. Its robust design ensures stable operation in environments where thermal expansion and mechanical stress are present. The valve is particularly suited for use in closed-loop systems where pump shutdowns could cause backflow issues. Proper installation and alignment are crucial to avoid leakage and premature wear.
Technical parameters
| Material | Brass CW617N |
|---|---|
| Operating temperature | +90 °C |
| Nominal pressure | PN 15 |
| Opening overpressure | 0.02 bar |
| Code | I08018400 |
| Brand | IVAR |
Installation and connection
Installation should be carried out in accordance with the manufacturer’s guidelines to ensure proper function and longevity. The valve is fitted with a 4 inch female flange (FF) connection, which requires matching male flanges on the adjacent pipework. Installers must verify that the flange faces are clean and free of debris before bolting the assembly. The tightening sequence should follow a crisscross pattern to ensure even pressure distribution and prevent leaks.
Common installation errors include misalignment of the flange faces and over-tightening of bolts, which can distort the flange and compromise the seal. A visual inspection after installation is recommended to confirm that all connections are secure and that the valve is positioned in the correct direction of flow. The valve must be installed in a straight pipe section to avoid stress on the body and internal components.
Compatibility and accessories
This valve is designed for compatibility with standard flanged piping systems using PN 15-rated components. It can be integrated into systems with brass or steel fittings provided the flange dimensions match the 4 inch FF specification. For complete system functionality, additional components such as isolation valves, pressure gauges, and flow meters may be required depending on the application. No specific accessories are mandatory for basic installation, but system-specific requirements may vary.
Technical background for designers
The IVAR EURA heavy check valve operates using a disc or flap mechanism that opens under forward flow and closes under reverse flow. The disc is guided by a polymer orifice, which ensures smooth movement and minimises wear. The brass CW617N body provides good corrosion resistance and mechanical strength, making it suitable for long-term use in water-based systems. The valve is certified for drinking water applications via ATEx standards.
System designers should consider the valve’s opening overpressure when calculating flow dynamics and pressure losses. The valve’s performance is influenced by the viscosity and temperature of the fluid, as well as the frequency of flow changes. Proper placement within the system is important to prevent cavitation and excessive turbulence, which can affect service life and efficiency.
Service and operation
Periodic inspection is recommended to ensure the valve continues to function correctly. Visual checks should include looking for signs of corrosion, leaks, or abnormal noise during operation. The flange bolts should be inspected for tightness, especially after initial operation when settling may occur. There are no specified service intervals provided in the technical documentation, but any deviation from normal operation should prompt further investigation.
During operation, the valve should open smoothly under forward flow and close securely when flow ceases. Any hesitation or resistance in the movement of the disc may indicate the need for cleaning or replacement of internal components. The polymer orifice and seating surfaces are not user-serviceable and should be replaced if damaged.
Frequently asked questions
Can the IVAR EURA heavy check valve be used in a hot water circulation system?
Yes, the valve is rated for a maximum operating temperature of +90°C, making it suitable for hot water systems.
What is the significance of the 0.02 bar opening overpressure?
This value indicates the minimum pressure differential required for the valve to open, ensuring reliable operation under normal flow conditions.
Is the valve suitable for installation in a closed-loop heating circuit?
Yes, the valve is appropriate for closed-loop systems where backflow prevention is required to protect pumps and other components.
Can the valve be connected to a system using male flanged pipework?
Yes, the valve features a female flange (FF) connection, which mates with a male flange of the same size and standard.
Additional parameters
| Category: | EURA check valves - heavy |
|---|---|
| Weight: | 13.5 kg |
| Product type: | check valve / flap |
| Thread size: | 2 1/2" and larger |
| Connection type: | flange |
| Material: | copper / bronze |
| Material: | brass CW617N |
| Nominal pressure: | PN 15 |
| Opening overpressure: | 0,02 bar |
| Operating temperature: | +90 °C |
| Posledná aktuálizacia ceny: | 13.04.2026 1:11:35 |