Wholesale e-shop

MOTOR 4GX TESLA 4" M - 2,2kW - 1x230V - double pole DAB.MOTOR 4GX

Code: 60141596
naparovana cena na magic
–20 %
Vykurovacia technika MOTOR 4GX TESLA 4" M - 2,2kW - 1x230V - dvojpólový
–20 % €1 084,18 / pcs €1 333,54 incl. VAT Measure price:
To order (1-2 weeks)

Detailed information

Product detailed description

This 4 inch double pole motor is commonly used in submersible pump systems for water supply, drainage, and irrigation in residential, commercial, and industrial applications. It is suitable for installation in wells, sumps, and other submersion environments where reliable and efficient pumping is required. The motor is designed to work with 4 inch diameter pumps and is compatible with both single-phase and three-phase electrical systems. The stainless steel AISI 316 construction ensures durability in corrosive environments, while the IP68 rating allows for full submersion without risk of water ingress.

The motor is typically installed below the water level and connected to the pump via a flange. The flat four-core cable allows for easy connection to the power supply. The system must be properly grounded and protected with appropriate overload and starting components to ensure safe and efficient operation. The motor is suitable for both light and heavy-duty applications depending on the selected protection and starting equipment.

Technical parameters

Code60141596
BrandIVAR
The motor operates on single-phase 1x230 V/50 Hz or three-phase 3 x 230 V/50 Hz and 3 x 400 V/50 Hz. These voltage options allow for flexibility in installation depending on the available electrical supply. The IP68 rating ensures complete protection against water ingress, making it suitable for continuous submersion. The insulation class F indicates the motor can operate at higher temperatures without degradation. The flange type is NEMA, which is a standard interface for connecting to 4 inch diameter pumps.Installation and connection The motor is installed below the water level and connected to the pump using a NEMA flange. The flat four-core cable is routed upwards from the motor and connected to the power supply. It is important to ensure that the cable is properly secured and protected from mechanical damage. The motor must be grounded and connected to a suitable starting system, such as a CONTROL BOX or CONTROL HS unit, depending on the load requirements. Common installation mistakes include improper grounding, incorrect cable routing, and failure to use the correct starting equipment. The motor should be tested for proper operation before being placed into service.Compatibility and accessories The motor is compatible with 4 inch diameter submersible pumps that use a NEMA flange connection. It is recommended to use a CONTROL BOX or CONTROL HS unit for starting and protection, depending on the load requirements. The motor is also compatible with single-phase and three-phase power supplies. Additional accessories such as cable glands, junction boxes, and overload protection devices may be required depending on the specific installation requirements.Technical background for designers The motor operates on the principle of asynchronous induction, where the rotor is driven by the rotating magnetic field generated by the stator. The stainless steel AISI 316 components provide resistance to corrosion and wear, ensuring long-term reliability in submersion environments. The motor is filled with an argon-based gas mixture to provide insulation and cooling for the stator. The radial and thrust bearings are lubricated and cooled by the surrounding liquid, which also helps to dissipate heat. The motor's performance and service life are influenced by factors such as the quality of the power supply, the load conditions, and the effectiveness of the starting and protection systems.Service and operation The motor requires minimal maintenance due to its sealed construction and robust design. However, it is important to periodically check the electrical connections and grounding to ensure safe operation. The motor should be inspected for signs of wear or damage, particularly in the bearings and seals. If the motor is not operating correctly, it may be necessary to check the starting system and overload protection. No specific service intervals are provided in the technical data, but regular inspections are recommended to ensure continued performance.Frequently asked questions

Can the motor be used with three-phase power supplies?
Yes, the motor is compatible with three-phase power supplies at 3 x 230 V/50 Hz and 3 x 400 V/50 Hz. The appropriate starting and protection equipment must be used for three-phase operation.

What type of starting system is required for this motor?
The motor can be started using a CONTROL BOX for general applications or a CONTROL HS system for heavier loads. The starting system must be selected based on the load requirements and electrical supply conditions.

Is the motor suitable for continuous operation?
Yes, the motor is designed for continuous operation in submersion environments. The IP68 rating and insulation class F ensure that the motor can operate reliably under normal conditions.

Can the motor be used with 4 inch diameter pumps?
Yes, the motor is specifically designed for use with 4 inch diameter pumps that use a NEMA flange connection. It is important to ensure that the pump and motor are compatible in terms of dimensions and performance requirements.

Additional parameters

Category: DAB.MOTOR 4GX - 4" submersible motors
Weight: 15 kg
Thread size: 2 1/2" and larger
Connection type: male thread
Posledná aktuálizacia ceny: 09.03.2026 0:10:56

Discussion

Be the first who will post an article to this item!

Do not fill out this field
Vytvořil Shoptet | Design Shoptak.cz.