Wholesale e-shop

Reducer - with one plug-in end - C - 108-76,1mm IVAR.IVC12

Code: IVC12.10876
naparovana cena na magic
–20 %
Vykurovacia technika Redukcia - s jedným zásuvným koncom - C - 108-76,1mm
–20 % €51,52 / pcs €63,37 incl. VAT Measure price:
4 - 7 days

Detailed information

Product detailed description

Steel reducers with one push-fit end are essential components in central heating, fire suppression, and industrial piping systems. These fittings are commonly used in closed-loop heating systems, chilled water circuits, and dry fire sprinkler systems. Installers and technicians working on commercial and industrial buildings often encounter these fittings during pipe layout and system expansion. The IVAR IVC12.10876 model is specifically designed for applications requiring a transition between different pipe diameters while maintaining system integrity and performance.

Such fittings are frequently used in HVAC systems, solar thermal installations, and compressed air lines. The push-fit connection allows for quick and secure installation without the need for welding or threading, reducing labor time and ensuring a leak-free seal. The operating temperature range and pressure rating make this reducer suitable for a wide range of environments, including those with fluctuating thermal conditions.

Technical parameters

Materialgalvanized carbon steel
Operating temperature-20 °C
Nominal pressurePN 16
Resistance to high pressures up to16 bar
Weight0.982 kg
CodeIVC12.10876
BrandIVAR

The operating temperature range from -20°C to +120°C allows the fitting to be used in both cold and hot water systems. The PN16 pressure rating indicates that it can handle up to 16 bar of working pressure, making it suitable for high-pressure applications. These parameters are critical for sizing and selecting the correct fitting for the intended system, ensuring long-term reliability and compatibility with other components.

Installation and connection

Installation of the IVAR IVC12.10876 involves connecting one end using a press-fit method and the other using a threaded or flanged connection, depending on the system design. The push-fit end requires the use of a compatible press tool and a sealing O-ring made from EPDM. The other end is typically threaded for connection to other components. It is important to ensure that the press-fit connection is fully seated and that the indicator mark is visible to confirm a secure fit.

Common installation mistakes include using incorrect tools for the press-fit connection or failing to check the alignment of the O-ring. To avoid leaks, the installer should verify that the pipe ends are clean and free from burrs before installation. The reducer should be installed in a straight line with no torsion or bending to prevent stress on the connection.

Compatibility and accessories

This reducer is compatible with press-fit systems using M-type clamps and EPDM O-rings. It is designed to be used with carbon steel pipes and other press-fit fittings in the IVAR range. When installing, it is necessary to ensure that all components are from the same system to maintain compatibility and performance. No additional accessories are required for standard installation, but it is recommended to have spare O-rings and a press tool on site for any adjustments or replacements.

Technical background for designers

The IVAR IVC12.10876 is a mechanical reducer that allows for a smooth transition between different pipe diameters. The EPDM O-ring ensures a tight seal and is resistant to a wide range of temperatures and media. The press-fit connection eliminates the need for welding or threading, reducing installation time and ensuring a consistent, high-quality connection.

When integrating this reducer into a system, designers should consider the thermal expansion of the piping and the potential for stress on the connection. The operating temperature range and pressure rating are key factors in determining the suitability of the fitting for the intended application. Proper system layout and support are essential to prevent mechanical stress and ensure long-term performance.

Service and operation

During operation, it is important to periodically inspect the reducer for signs of wear, corrosion, or leakage. The press-fit connection should be checked for any movement or misalignment, and the O-ring should be inspected for any signs of degradation. If any issues are detected, the fitting should be replaced immediately to prevent system failure. No specific service intervals are provided for this model, but regular visual inspections are recommended as part of routine system maintenance.

Frequently asked questions

Can the IVAR IVC12.10876 be used in fire suppression systems?
Yes, it is suitable for use in dry fire sprinkler systems and other fire suppression applications due to its pressure and temperature ratings.

Is the reducer compatible with other press-fit systems?
It is compatible with press-fit systems using M-type clamps and EPDM O-rings, but not all press-fit systems are interchangeable.

Can the reducer be used in solar thermal systems?
Yes, it is suitable for solar thermal installations due to its operating temperature range and resistance to thermal cycling.

Is the reducer suitable for use with compressed air?
Yes, it is suitable for use with inert gases and compressed air, provided the pressure and temperature conditions are within the specified limits.

Additional parameters

Category: IVAR.IVC12 - reduced couplings
Warranty: 2 years
Weight: 0.982 kg
Product type: reducer / adapter
Pipe diameter: 63 mm and larger
Material: steel / cast iron
High pressure resistance up to: 16 bar
Material: galvanized carbon steel
Nominal pressure: PN 16
Operating temperature: -20 °C
Posledná aktuálizacia ceny: 13.04.2026 1:12:14